Skip to content
Browse the whole research Library · Start page for AI agents ·

CUPCA 2004 APPENDICES ALLOCATION AND POWER RECEIPT

.json · 1 sections · 10731 characters

Source, owner, and dates

workbench: _Working/federal-budget-2026-2027/goal/terra_process/interior/upstream_cupca/batch2/CUPCA_2004_APPENDICES_ALLOCATION_AND_POWER_RECEIPT.json

Canonical source SHA-256: 44ee350c646bebfc159b40d8e82c16ccc12fb81b98299df868852f7160fb765b

Served copy SHA-256: 44ee350c646bebfc159b40d8e82c16ccc12fb81b98299df868852f7160fb765b

Owner evidence cutoffs: {"federal-budget-fy2026-fy2027": "2026-09-11T19:55:13-04:00"}

These are package-level cutoffs, not a claim that this source was rechecked on those dates. Use its own publication and capture dates.

Owners: federal-budget-fy2026-fy2027

complete text

Opening section

Section 1 of 1

{ "artifact_type": "bounded_original_appendix_read_receipt", "created": "2026-09-11", "question": "Recover the Financial and Economic Appendix and Power Appendix named by the October 2004 Bonneville Unit Supplement, inspect the allocation/power analysis actually supplied by them, and reconcile the main-report page map.", "identity_and_retrieval": { "current_identity_page": "https://www.doi.gov/cupcao/bonneville-unit-2004-supplement-1988-definite-plan-report-dpr", "archive_cdx_query": "https://web.archive.org/cdx/search/cdx?url=www.cupcao.gov/docs/BU-DPR/*&output=json&filter=statuscode:200&filter=mimetype:application/pdf&fl=timestamp,original,statuscode,mimetype,digest,length&collapse=urlkey", "former_official_publication_urls_and_archived_delivery": [ {"object":"Financial and Economic Appendix, Part 1","former_official_url":"http://www.cupcao.gov/docs/BU-DPR/Supp-DPR-FinEcon-Appdx-Part1.pdf","archive_timestamp":"20120915082741","archived_delivery_url":"https://web.archive.org/web/20120915082741id_/http://www.cupcao.gov/docs/BU-DPR/Supp-DPR-FinEcon-Appdx-Part1.pdf","pdf_pages":138,"sha256":"ff7de7235c3d52c3bf76b495e25f493fc3f2e95c1f4738343202444ac852540d","local_path":"/tmp/cupca_finecon_part1.pdf"}, {"object":"Financial and Economic Appendix, Part 2","former_official_url":"http://www.cupcao.gov/docs/BU-DPR/Supp-DPR-FinEcon-Appdx-Part2.pdf","archive_timestamp":"20120915082949","archived_delivery_url":"https://web.archive.org/web/20120915082949id_/http://www.cupcao.gov/docs/BU-DPR/Supp-DPR-FinEcon-Appdx-Part2.pdf","pdf_pages":146,"sha256":"11262acef450a798d04075f876a645fcf0881b2366f05cba8aac458afe3cf8c3","local_path":"/tmp/cupca_finecon_part2.pdf"}, {"object":"Power Appendix","former_official_url":"http://www.cupcao.gov/docs/BU-DPR/Supp-DPR-Power-Appdx.pdf","archive_timestamp":"20120915083834","archived_delivery_url":"https://web.archive.org/web/20120915083834id_/http://www.cupcao.gov/docs/BU-DPR/Supp-DPR-Power-Appdx.pdf","pdf_pages":134,"sha256":"d2c5b80fad539a3790d983f14f289c523bbdd7c5c26d4bfbb6f40b80b3e4d425","local_path":"/tmp/cupca_power_appendix.pdf"} ], "identity_conclusion":"All three covers identify themselves as October 2004 supporting appendices to the Supplement to the 1988 Definite Plan Report for the Bonneville Unit. The publicly indexed former CUPCA.gov filenames supply exact appendix identities. Current DOI verifies the parent document identity; the appendices themselves were read from transparently archived former-official deliveries, not claimed as current DOI-hosted files." }, "appendix_inventory": { "financial_and_economic":"Two-part, 284-PDF-page file set. Part 1 includes Chapters 1–6, Chapter 6 allocation tables, and supporting material; Part 2 begins Chapter 7 Project Repayment, its tables/references, then Attachment A correspondence and further material. Only allocation/recovery/authority sections below were substantively read.", "power":"134-PDF-page appendix with Chapters 1–6 and Attachment A (Optimization of Installed Capacity). Its table of contents has no Chapter 7. It contains Chapter 2 methodology/sizing and Chapter 6 financial and economic analyses." }, "read_scope": { "financial_economic_part1":"PDF pp.1–6 (cover/contents); pp.70–105 (entire Chapter 6 prose); pp.106–138 (all Chapter 6 tables).", "financial_economic_part2":"PDF pp.1–35 (entire Chapter 7 and its tables/references); pp.36–49 (Attachment A cost-allocation correspondence, including reproduced GAO/Interior material).", "power":"PDF pp.1–6 (cover/contents); pp.17–25 (entire Chapter 2 methodology/sizing); pp.64–71 (entire Chapter 6 financial/economic analysis and tables).", "not_read":"Other Financial and Economic Appendix chapters/material after the described scope, Power Appendix Chapters 1 and 3–5 and Attachment A, and source documents named in the appendices were not fully read. Tables were inspected as displayed; no independent recomputation or audit of inputs was performed." }, "financial_economic_findings": [ {"locator":"Part 1 PDF pp.70–73 / printed 6-1 to 6-4","finding":"The appendix expressly displaces prior Bonneville Unit SCRB work with UOF. It says the January 1994 GAO letter recommended UOF because more sophisticated approaches required data that were not reliably available or would be costly/time-consuming to update. The appendix reproduces related correspondence in Attachment A.","limit":"This is the appendix's account of GAO direction; the reproduced correspondence was read but the underlying GAO Central Valley report and statutes were not independently reviewed in this batch."}, {"locator":"Part 1 PDF pp.73–76 / printed 6-4 to 6-7","finding":"UOF catalogs costs by authorization/funding/feature/use; allocates Section 8; identifies specific costs; applies assigned joint costs by facility capacity/yield and water use; distributes remaining joint costs according to each purpose's specific plus assigned costs; and summarizes the result. It relies on D&E Appendix costs, stated IDC tables, and hydrologic/capacity tables.","limit":"The D&E Appendix and underlying water/cost records were not read; this establishes the stated calculation design, not input validation."}, {"locator":"Part 1 PDF pp.77–80 and pp.125–138 / printed 6-8 to 6-11 plus Tables 6-6 to 6-15","finding":"The six implementation principles include tracing water to origin, multiple-counting nonconsumptive uses, facility-specific treatment of pre-existing rights, power marketability, present-value treatment of the 30,000 AF South Utah County block, and minimizing remaining joint costs. Table 6-15 supplies the block calculation; Chapter 6 says remaining joint costs were kept below 1% of assigned joint costs.","limit":"The document labels this an allocation result. It does not provide an external validation study or uncertainty/sensitivity analysis for the allocation inputs."}, {"locator":"Part 1 PDF pp.78–80, 129–131 / printed 6-9 to 6-11 and Tables 6-10 to 6-12","finding":"A full UOF tracing of power would allocate more than $540.3m. Modified UOF instead caps power costs at expected sales revenue plus lease-of-power-privilege revenue, local cost share, and nonreimbursable abandoned-power-investigation offsets; it retains the unmodified UOF facility percentages to spread the constrained amount. The tables show the development of this marketability cap.","limit":"This is a methodological and forecast-based constraint, not empirical proof of market proceeds or executed repayment."}, {"locator":"Part 2 PDF pp.2–12 and pp.25–35 / printed 7-1 to 7-11 and Tables 7-1 to 7-13","finding":"Chapter 7 converts allocation to repayment categories, local cost share, contract/Section 211 treatment, and irrigation/M&I/power obligations. For power it reports about $161.0m allocated under modified UOF and about $132.9m after deductions, amortized over 50 years at 3.222%, with modeled annual payment about $5.4m. It says a future DOI–District–Western contract would establish payment, operation, marketing and remittance arrangements.","limit":"These are October 2004 projected calculations and anticipated contractual arrangements, not evidence of later execution or current CUPCA financial status."} ], "power_appendix_findings": [ {"locator":"PDF pp.17–25 / printed 2-1 to 2-9","finding":"The sizing analysis used flow, operating, turbine, transmission, cost, OM&R, energy-benefit and economic assumptions. It evaluated ranges of plant flow/capacity and selected capacity by NPV, while stating that this optimization was only for installed-capacity selection and was not valid or recommended for prescribed Bonneville Unit benefit/cost or cost-allocation use. It flags the 45 MW FEIS assumption and a subsequent 40 MW optimum for Sixth Water, with a 5 MW Upper Diamond Fork cable constraint.","limit":"The source data, FEIS, power-flow model, and optimization spreadsheet were not independently verified."}, {"locator":"PDF pp.64–71 / printed 6-1 to 6-8","finding":"Power Appendix Chapter 6 reprises the project B/C comparison with and without power, then applies UOF to an annual block of 94,726 AF and lists the facilities receiving assigned joint power costs. It repeats that strict UOF exceeded $540.3m; modified UOF yields about $161.0m allocation and about $132.9m net repayment obligation. It says the expected revenue/offset package determines that cap and estimates OM&R at 13.1 mills/kWh, while actual annual OM&R would vary with expenses.","limit":"The analysis itself separates the optimization analysis from the prescribed allocation method. Its marketability and revenue figures are assumptions/forecasts, not performance validation."} ], "main_report_page_map_correction": { "parent_document":"/tmp/cupca_supplement_2004.pdf", "map":"PDF p.208 = printed DPR 9-10; p.209 = 9-11; p.210 = 9-12; p.211 = 9-13; p.212 = 9-14; p.213 = 9-15; p.214 is Table 9-10 and corresponds sequentially to printed 9-16; p.215 begins Table 9-11 / printed 9-17.", "clarification":"Thus the earlier shorthand ‘main report pp.209–214’ crosses printed DPR 9-11 through the Table 9-10 page, rather than beginning at 9-10. The allocation-method prose begins on PDF p.209 / printed 9-11; PDF p.208 holds IDC/B-C context and Table 9-8." }, "power_locator_discrepancy": { "main_report_statement":"The parent report refers to a comparative with/without-power analysis in ‘Chapter 7 of the Power Appendix.’", "recovered_appendix_contents":"The recovered October 2004 Power Appendix has Chapters 1–6 only. The comparative with/without-power analysis appears in Chapter 6, PDF pp.64–65 / printed 6-1 to 6-2.", "disposition":"Do not silently normalize the locator. The recovered appendix otherwise identifies the same parent October 2004 Supplement, but this Chapter 7/Chapter 6 discrepancy remains a document-locator issue; no alternate Power Appendix edition was established or excluded." }, "bounded_limits_and_followup": [ "The archive index establishes retrievable former-official URLs but does not by itself establish current DOI hosting or later revision history.", "A proper audit of the allocation would require the D&E Appendix, hydrologic/capacity data, source contracts, GAO Central Valley report/1994 directions, and legal authority review; none is implied by reading the appendices.", "No 2004 revenue, cost, repayment, or capacity projection is a FY2027 amount or evidence of current compliance without a later accounting/execution bridge.", "If precise version reconciliation is needed, seek a DOI-held copy or revision metadata for the Power Appendix to resolve its Chapter 7 reference." ] }